SHOCK BLOCK CLASS D SPGFCI 600V 32A
Image may not reflect selected features
SHOCK BLOCK CLASS D SPGFCI 600V 32A (SB5032-301-0)
Special-Purpose Ground-Fault Circuit Interrupter (SPGFCI), Class C and Class D: Industrial Shock Block (ISB) is a personnel protection device designed to meet the requirements for special-purpose GFCIs defined by UL 943C. This standard outlines GFCI classes specifically designed for use in industrial facilities. Class C GFCIs are intended to be used on three-phase systems where the line-to-line voltage is 480 V or less with a trip level of 20 mA, while Class D GFCIs are intended to be used on 600 V systems. The Industrial Shock Block includes DFT harmonic filtering, an automatic self-test feature and is compliant to the UL 1998 Software in Programmable Components standard. Ground-Fault Circuit Interrupter (GFCI), Class A: The Shock Block is available as a 208 V Class A GFCI, allowing commercial kitchens, construction sites, and other non-dwelling units with wet areas to meet NEC 210.8(B) for their 3-phase loads up to 60 A. Equipment Ground-Fault Protective Device (EGFPD): Industrial Shock Block is also available with adjustable protection settings as an EGFPD. The EGFPD models can be set to trip at 6 mA or from 10–100 mA in increments of 10 mA. This offers more flexibility since GFCI devices are not allowed to have an adjustable trip level. Rating and Models: Industrial Shock Block (GFCI & EGFPD) is available for threephase voltages from 208 to 600 V with a maximum full load current of either 32 or 60 A. The power system can be either solidly or high-resistance grounded and the load must be three phase without a neutral. The standard enclosure is IP 69K/NEMA 4X and outdoor rated, suitable for all industrial environments including hightemperature washdown used in food production. A Class II, Division 2 option is also available for applications where explosive dust may be present. Ground Wire (Load-Ground) Monitor: The Industrial Shock Block also monitors the ground wire (load-ground) connection between the Industrial Shock Block and load. This is a required feature for Class C and D GFCI devices and is recommended for Class A GFCI and EGFPD devices. If the ground-return path is broken, the Industrial Shock Block will trip and provide an alarm by changing the state of the alarm contacts. This monitoring circuit includes an extra wire (pilot wire) between the Industrial Shock Block and load. At the load, the pilot wire is connected to a termination device. The other end of the termination device is connected to the load ground (typically the enclosure).
Product Specification
Item #
SB5032-301-0
Dimensions
Height: 11.25"
Width: 9.56"
Length: 4.44"
Additional product details
Electrical Category
Fuses Relays And Circuit Breakers
Electrical Subcategory
Circuit Protection Devices And Accessories
Electrical Subtype
Circuit Interruptor
Brand Name
Littelfuse
Country Of Origin
MX
Order Minimum
1.000 EA
Order Multiple
1.000 EA
RoHS Compliance
Contact Manufacturer
Spec Sheet
Stock Type
Shelf Stock
Sub Brand
Industrial Shock Block
UNSPSC
39121633
Video Clip